ACCA Manuals J, S, and D are referenced and required across America. This form provides a quick and easy review of the HVAC system design. This review gives an objective indication of whether the required processes were followed.

  • Manual J Load Calculations: Estimates for the heating and cooling required for a residence are correct.
  • Manual S Equipment Selection: Equipment selection was based on the heating and cooling loads and OEM performance data; the equipment is within the maximum sizing requirements.
  • Manual D Duct Systems: The duct sizes were based on the equipment selected, duct system geometry, fittings, and duct materials used.

The form is meant to be simple; it is neither exhaustive nor exclusive. Hundreds of elements in the load calculation, equipment selection, or duct design could be verified. This form seeks to examine only a few very simple items, in each design stage that directly impact the occupants' health and safety. The form is meant to stand alone and be enforced immediately. However, it could serve as the basis for an expanded form when the code officials have an increased understanding of the processes, or it may be modified to address regional concerns.

The contractor's completed form may be supported with copies of standard load calculation forms, OEM performance data, and other worksheets. This form is impartial to any particular software developer. However, they have examined the form and are investigating the development of simple print commands that facilitate its completion and supplemental documentation.

#Residential #QualityStandards #ManualJ #ManualD #ManualS

Statistics
4 Favorited
1456 Views
5 Files
0 Shares
44392 Downloads
Attachment(s)
pdf file
ACCA HVAC Plan Review 2024 - UMC.pdf   179 KB   1 version
Uploaded - 09-18-2024
doc file
Instructions HVAC Plan Review April 2024.doc   2.28 MB   1 version
Uploaded - 04-26-2024
pdf file
ACCA HVAC Plan Review 2024.pdf   182 KB   1 version
Uploaded - 03-18-2024
pdf file
Illustrated Example #1   1.72 MB   1 version
Uploaded - 06-23-2015
This illustrated example demonstrates the full ANSI-recognized Manual J procedure. The example equipment selection process demonstrates where to find the information needed for an HVAC system consisting of a furnace and air conditioner. Circled numbers on HVAC Systems Design Review Form correspond to the descriptions in the introduction and to the locations where the information can be found on the supporting documentation.
pdf file
Illustrated Example #2   1.82 MB   1 version
Uploaded - 06-23-2015
This illustrated example demonstrates the Manual J Abridged Edition (AE) procedure. The Manual JAE condenses the basic elements of the load calculation into a functional procedure to promote comprehension in students. Manual J1AE load calculations are valid however; they must meet all of the requirements on the Alternative Abridged Edition Check List (included on page 6). The example equipment selection process demonstrates where to find the information needed for a heat pump HVAC system.